0

Currency

0.0%

Balance system SD

    This combination does not exist.

    Request Price

    Static and dynamic balance testing and training -- for athletes to older adults from Biodex.


    Code
    106-561
    Brand
    Origin
    United States
    Warranties
    Usage
    Man Animal
    Type
    Medical
    Licence
    102599
    Class
    2

    Our product offering is among the most distinctive, unique and very often exclusive! It is based on a rigorous selection of high quality products, supplies, instruments and medical equipment from the best manufacturers in the world. This philosophy has allowed Atlas Médic to define its identity in terms of quality and to become one of the few distributors of medical instruments manufacturing its own products and offering a complete corporate ecosystem including 
    training,  consulting services and technical services

    Consult our policies  and code of ethics. to make sure you are eligible to make the purchase. If you have any questions, do not hesitate to ask for information  from one of our expert advisors.

    • User capacity: 27-182 kg (60-400 lb)

    • Weight: 107 kg (235 lb)

    • Base dimensions: 66 cm (26 ") x 94 cm (37") x 20 cm (8 ")

    • Platform dimensions: 55 cm (21.5 ") in diameter

    • All-in-one flat screen PC included

    • Screen height: 117cm (46 ") to 152cm (60") from center of screen to platform

    • Stability levels: 12 dynamic levels, more locked for static measurements

    • Platform tilt: 20 ° from horizontal in all directions

    • Support handles: adjustable from 66 cm (26 ") to 93 cm (36.5") above the platform  

    • Printer included

    • Printer stand: 61 cm (24 ") x 61 cm (24") 

    • Power supply: 115 VAC, 50/60 Hz, 15 amp line

    • Power:  350 watts 

    Meeting multiple clinical needs with a single tool

    Contact us and find out how the Balance system SD can help you.

    Multiple Applications and Pathologies with a Single Investment

    Neuroréhabilitation

    The training exercises of the Balance System SD are geared to improve strength, range of motion, gait and balance for those patients suffering from neurological involvement associated with Parkinson’s, Stroke or Peripheral Neuropathy. In practice, the Balance System can capture, quantify and document a patient’s relative tendency to overcompensate to one side or the other. This information can often determine a true course of treatment.

    Concussion Management

    Biodex Balance Assessment for Concussion Management is used by high school, college, and professional sports teams to unravel the mystery of concussion and to bring together best practices combining cognitive testing and a graded symptoms checklist in combination with balance assessment. The Balance System is an objective Balance Assessment tool that provides a performance baseline against which post-injury performance can be compared aiding with return-to-play decisions.

    Réadaptation pour personnes âgés

    Tackling the needs of the older adult requires an understanding of the complex physiology of this population segment. As part of the Balance & Mobility product series, the Balance System SD addresses age related diseases by aiding in increasing mobility, addressing fall risk, improving balance, developing muscle tone and increasing agility.

    Troubles vestibulaires 

    The Balance System SD is an evaluation tool, as well as a rehabilitative device, ideal for patients experiencing vestibular issues. Balance retraining exercises are designed to steady a patient while walking or standing through improvements in coordination of muscle responses and organization of sensory information. Static and dynamic tests are administered to gauge a patient’s balance – objective reporting and comparisons to normative data aid in the development of individual exercise plans.

    Médecine du sport / orthopédie

    Help athletes perform better by demonstrating functional deficits. The Biodex Balance System documents weakness and challenges patients to improve. The various test modes evaluate the athlete in a static or dynamic environment, and then generates objective documentation of the results. Reports include standard deviations of target performance, the percentage of time an athlete stays in a particular quadrant and then compares performance to normative data, built into the system. This allows the objective measures of the athlete to be trained, and then easily reevaluated and assessed to quantify improvement.


    Broaden Your Applications.
    Increase Your Clinical Value!

    The Balance System SD offers:

    • Static and Dynamic (SD) – Offers 12 levels of platform control as well as static force setting.

    • Balance Training – Includes proprioception, stabilization, range of motion and weight shift exercises.

    • Fall Risk Screening Test Protocol – Standardized protocol that compares balance test results to age-dependent normative data.

    • Software and Larger Display – Intuitive navigation, 15.6" touchscreen display for improved user experience. Accommodates external keyboard and mouse.

    • Microsoft SQL Database – Allows clinician to easily store and retrieve patient data, multiple tests per patient. Export to Excel® for reporting and analytics.

    • Objective Documentation – Printed color reports prove need, track progress and document outcomes – ideal for insurance reimbursement.

    • Concussion Management Protocol – For preseason baseline testing and post-injury return-to-play management. Compare to age-dependent normative data using modified Clinical Test for Sensory Integration of Balance (mCTSIB).

    • Normative Data – Healthy populations stored for test comparison of older adults for fall screening and student athletes for concussion management.

    • Audio/Visual Biofeedback – Motivates patient by prompting proper balance control in real-time. Allows clinician to easily monitor patient during interactive testing/training.

    • Multipurpose Connectivity – Allows connection to larger monitors and projectors to enhance interaction for visually impaired patients. 

    • Locking Surface – Helps ensure patient safety while moving on or off platform.

    • Mobility – Transport wheels allow easy relocation between clinic and community for fall screening programs and health fairs.

    The most popular Balance System…now even better 

     

    The Biodex Balance System SD has been designed to meet the needs of everyone looking to improve balance, increase agility, develop muscle tone and treat a wide variety of pathologies. Featuring easy-to-follow “touchscreen” operation, the Balance System SD is simple to learn and operate, leading the user step-by-step through testing protocols and training modes in both static and dynamic formats. Extremely versatile, it is the only system that provides a fast, accurate Fall Risk Screening and Conditioning Program for older adults; closed-chain, weight-bearing assessment and training for lower extremity patients, and adds the objective balance assessment component to a concussion management program.  

    The Balance System SD also serves as a valuable training device to enhance kinesthetic abilities that may provide some degree of compensation for impaired proprioceptive reflex mechanisms following injury. Using this unique device, clinicians can assess neuromuscular control by quantifying the ability to maintain dynamic bilateral and unilateral postural stability on a static or unstable surface.

     


     
     


    Odoo - Echantillon n°1 pour trois colonnes

    Screening and conditioning

    The Balance System SD includes a comprehensive Fall Risk Screening & Conditioning Program and Protocol, consistent with American Geriatrics Guidelines. Identify a person at risk to fall in just two minutes by comparing their balance test results to age-dependent normative data. 

    Odoo- Echantillon n° 2 pour trois colonnes

    Simplicity 

    The Balance System SD is simple to use with an intuitive touchscreen. Patients require minimal supervision and can progress through the different levels at their own pace. The training exercise includes static and dynamic balance activities, weight transfer, increasing stability limits, and improving reaction time. The system produces color reports to provide motivating feedback.

    Odoo- Echantillon n° 3 pour trois colonnes

    Objectify

    Prove Need. Progress. Outcome – All test results and training sessions can be stored and printed. Comparison to normative data helps communicate need, progress and outcome.



    Here is our selection of documents

    Learn more about the Balance system SD

    Technical sheet 

    Balance system SD - EN

    User manual 

    User manual - EN 

    Nos suggestions